import pytest
|
|
|
|
from v1.fall_state import Evidence, FallState, FallStateMachine
|
|
|
|
|
|
CONFIG_VERSION = "cfg-test-20260721"
|
|
|
|
|
|
def test_confirmed_event_is_emitted_once_after_persistent_evidence():
|
|
machine = FallStateMachine(
|
|
confirm_window_seconds=1.8,
|
|
recovery_window_seconds=2.0,
|
|
config_version=CONFIG_VERSION,
|
|
)
|
|
|
|
assert machine.update("P-0007", Evidence(True, True), now=0.0) == []
|
|
events = machine.update("P-0007", Evidence(True, True), now=1.8)
|
|
|
|
assert len(events) == 1
|
|
assert events[0].track_id == "P-0007"
|
|
assert events[0].latency_seconds == 1.8
|
|
assert events[0].config_version == CONFIG_VERSION
|
|
assert machine.update("P-0007", Evidence(True, True), now=2.0) == []
|
|
assert machine.state_of("P-0007") is FallState.CONFIRMED
|
|
|
|
|
|
def test_brief_low_posture_returns_to_normal_without_event():
|
|
machine = FallStateMachine(
|
|
confirm_window_seconds=1.0,
|
|
recovery_window_seconds=2.0,
|
|
config_version=CONFIG_VERSION,
|
|
)
|
|
|
|
machine.update("P-0007", Evidence(True, True), now=0.0)
|
|
events = machine.update("P-0007", Evidence(True, False), now=0.3)
|
|
|
|
assert events == []
|
|
assert machine.state_of("P-0007") is FallState.NORMAL
|
|
|
|
|
|
def test_rejected_pose_resets_suspect_and_cannot_shorten_confirmation_window():
|
|
machine = FallStateMachine(
|
|
confirm_window_seconds=1.0,
|
|
recovery_window_seconds=2.0,
|
|
config_version=CONFIG_VERSION,
|
|
)
|
|
|
|
machine.update("P-0007", Evidence(True, True), now=0.0)
|
|
machine.update("P-0007", Evidence(False, False), now=0.9)
|
|
events = machine.update("P-0007", Evidence(True, True), now=1.1)
|
|
|
|
assert events == []
|
|
assert machine.state_of("P-0007") is FallState.SUSPECT
|
|
|
|
|
|
def test_recovery_must_persist_before_new_event_is_allowed():
|
|
machine = FallStateMachine(
|
|
confirm_window_seconds=1.0,
|
|
recovery_window_seconds=2.0,
|
|
config_version=CONFIG_VERSION,
|
|
)
|
|
machine.update("P-0007", Evidence(True, True), now=0.0)
|
|
first_event = machine.update("P-0007", Evidence(True, True), now=1.0)
|
|
assert len(first_event) == 1
|
|
|
|
machine.update("P-0007", Evidence(True, False, True), now=1.1)
|
|
machine.update("P-0007", Evidence(True, False, True), now=3.1)
|
|
assert machine.state_of("P-0007") is FallState.NORMAL
|
|
|
|
machine.update("P-0007", Evidence(True, True), now=4.0)
|
|
second_event = machine.update("P-0007", Evidence(True, True), now=5.0)
|
|
assert len(second_event) == 1
|
|
assert first_event[0].event_id != second_event[0].event_id
|
|
|
|
|
|
def test_confirmation_window_must_remain_within_customer_target():
|
|
with pytest.raises(ValueError, match="between 1 and 3"):
|
|
FallStateMachine(
|
|
confirm_window_seconds=0.9,
|
|
recovery_window_seconds=2.0,
|
|
config_version=CONFIG_VERSION,
|
|
)
|
|
|
|
|
|
def test_each_track_has_an_independent_confirmation_window():
|
|
machine = FallStateMachine(
|
|
confirm_window_seconds=1.0,
|
|
recovery_window_seconds=2.0,
|
|
config_version=CONFIG_VERSION,
|
|
)
|
|
|
|
machine.update("P-0001", Evidence(True, True), now=0.0)
|
|
machine.update("P-0002", Evidence(True, True), now=0.6)
|
|
first_events = machine.update("P-0001", Evidence(True, True), now=1.0)
|
|
second_events = machine.update("P-0002", Evidence(True, True), now=1.6)
|
|
|
|
assert first_events[0].track_id == "P-0001"
|
|
assert second_events[0].track_id == "P-0002"
|
|
assert first_events[0].event_id != second_events[0].event_id
|
|
|
|
|
|
def test_cooldown_delays_recovery_after_confirmation():
|
|
machine = FallStateMachine(
|
|
confirm_window_seconds=1.0,
|
|
recovery_window_seconds=2.0,
|
|
config_version=CONFIG_VERSION,
|
|
cooldown_seconds=3.0,
|
|
)
|
|
machine.update("P-0007", Evidence(True, True), now=0.0)
|
|
machine.update("P-0007", Evidence(True, True), now=1.0)
|
|
|
|
machine.update("P-0007", Evidence(True, False, True), now=1.1)
|
|
assert machine.state_of("P-0007") is FallState.CONFIRMED
|
|
|
|
machine.update("P-0007", Evidence(True, False, True), now=4.0)
|
|
assert machine.state_of("P-0007") is FallState.RECOVERING
|